DKZ Series Electronic Flexure Testing Machine
1 Important function
1) Test and research with cement mortar, oil well cement for flexure strength and mechanical property.
2) Test and research with concrete road brick, calcium carbonate board, concrete tile, wall brick for flexure strength and other properties.
3) Test and research with ceramic brick, asbestos cement wave tile, asbestos cement flat board, straw board, gypsum board, light thermal insulation and wooden board flexure strength and mechanical property.
4) Test and research with nonmetallic compounding material for flexure property.
5) Test and research with bond mortar and variety of building thermal insulation material for shearing bond strength and other properties.
6) Test and research with implantation material of surgery department, bone fracture plate for flexure strength and other properties.
7) Test and research for 3 points bending strength and 4 points bending flexure strength.
Test and research according to GB, ISO, ASTM, DIN, BS.
2 Important specification
No. |
Item |
Specification |
1 |
load capacity |
5kN/10kN/20kN |
30kN/50kN |
2 |
grade of test machine |
0.5/1 |
3 |
range of load |
0.4% -- 100%FS(grade of 0.5)/1% -- 100%FS(grade of 1) |
4 |
relative error of indicated value |
between ±0.5%(grade of 0.5)/±1.0%(grade of 1) |
5 |
resolution of load |
1/±200000FS(for full scale) |
6 |
range of deformation |
0.2% -- 100%FS |
7 |
range of force speed |
0.005% -- 5%FS/s |
8 |
precision of force speed |
speed is less than 0.05%FS, between ±1% of set value.
speed is more than 0.05%FS, between ±0.5% of set value. |
9 |
range of deformation speed |
0.005 – 5%FS/s |
10 |
precision of deformation speed |
speed is less than 0.05%FS/s, between ±1% of set value.
speed is more than 0.05%FS/s, between ±0.5% of set value. |
11 |
range of displacement speed |
0.2 – 600mm/min |
12 |
precision of displacement speed |
between ±0.2% of set value. |
13 |
range of constant force, deformation and displacement |
0.5% -- 100%FS |
14 |
precision of constant force, deformation and displacement |
set value is more than 10%FS, between ±0.5% of set value.
set value is more than 10%FS, between ±1% of set value. |
15 |
effective span |
400mm |
16 |
stroke of transom |
600mm/customizable |
17 |
voltage |
220V±10%, 50Hz(reliable landing) |
18 |
power |
400W |
750W |
19 |
size of load frame |
860*460*750mm |
940*520*850 |
20 |
weight |
200kg |
300kg | |